format zfs – Geospatial Modeling & Visualization / A Method Store for Advanced Survey and Modeling Technologies Thu, 22 Mar 2018 11:49:17 +0000 en-US hourly 1 https://wordpress.org/?v=6.9.4 Z+F Laser Scanner: Starting your Scan /uncategorized/z-f-laser-scanner-scanning-your-target-2/ Wed, 07 Mar 2012 17:10:47 +0000 /?p=4790 Continue reading →]]> This workflow will show you how to start a scan using the Z+F Laser Scanner.
Hint: You can click on any image to see a larger version.

[wptabs style=”wpui-alma” mode=”vertical”] [wptabtitle] POSITIONING AND POWERING UP THE SCANNER[/wptabtitle] [wptabcontent]

1. Position the scanner in the center of the target field

Ensure that the angle of incidence of the laser on the target is larger than 45 degrees

 

Recommended distance between the Z+F scanner and targets

RESOLUTION RECOMMENDED DISTANCE WITH AN ANGLE OF 90 deg.
Middle 1 m to 15 m
High 1 m to 20 m
Super High 1 m to 25 m
Ultra High 1 m to 30 m

With smaller a smaller angle of incidence the target distance is reduced

Power the scanner on by pressing the power button for 0.3 seconds

The power-up process takes approx. 20 seconds in which time it will rotate while the mirror spins

[/wptabcontent]

[wptabtitle] MENUS AND CONTROLS[/wptabtitle] [wptabcontent]

Menus and Controls

System Menu shown in the display. Main menu order:

· Info

· Status

· Tilt Sensor

· Scanning

· Data Management

Control buttons:

clip_image004[/wptabcontent]

[wptabtitle]SCAN MENU SYMBOLS[/wptabtitle]

[wptabcontent]Scan Menu Symbols

The top line indicates the menu currently in use

clip_image006

See User Manual for full descriptions of all menus

Check the Tilt Sensor Menu

If the inclination in f the Y-direction is greater than or less than 2 degrees, an arrow will appear and the inclination should be corrected[/wptabcontent]

[wptabtitle] THE SCANNING MENU[/wptabtitle] [wptabcontent]In the Scanning Menu

RESOLUTION:

Select the preferred resolution level (Middle or High is usually preferred)

Super High, High and Middle resolutions have a low noise option that reduces noise by the factor of 1.4, but scanning time is doubled

VERTICAL SCAN RANGE:

You can select predefined vertical scan ranges using the + / – buttons or further refine each predefined range by pressing the clip_image007 button and increasing or decreasing the values by 5 deg. with the + / – buttons. Predefined ranges include:

· V 0-360

· V 25-160 and 200-335

· V25-180

· V 180-260

· V 45-135

HORIZONTAL SCAN RANGE:

The horizontal scan range can be set in increments of 5 deg. for both the start and end position using the + / – buttons and pressing the clip_image008 button to confirm the position

Alternatively the scanner start position can be manually set by rotating the scanner to any position greater than 0.0. Press the clip_image009 button to confirm the position. Set the horizontal range end position next in the same manner[/wptabcontent]

[wptabtitle] START THE SCAN[/wptabtitle]

[wptabcontent]Start the Scan

Press the clip_image010 button to start the scanning process. The process can also be stopped using this button and all data collected prior to interruption will be stored.
[/wptabcontent]

[/wptabs]

]]>
University of Arkansas – Vol Walker Building – Interior Floor 2 /region-data/region/united-states/university-of-arkansas-vol-walker-building-interior-floor-2-2/ Tue, 30 Aug 2011 00:50:10 +0000 /?p=3634 Continue reading →]]>  

Working with the University of Arkansas’ Facilities Management and Planning Departments, CAST is documenting the historical Vol Walker Building and its renovation.  Here are merged scans of the second floor of the interior, which were collected with the Z+F 5005i Scanner.  The project includes multiple floors within the building interior as well as the building exterior.  Interior scans were collected with a point spacing that ranged from less than a centimeter at the most dense (at a range of < 1 meter) to approximately 5 cm at the least dense (at a range of 25 meters).  These scans were then reduced to a more consistent point spacing of 1 cm for potential future use in historical preservation documentation.  Exterior scans were collected with a point spacing of approximately 5-10 cm.  The data sets have been separated due to file size and data density.

Vol_Walker_Building_Interior_Floor_2 .zip (2.81 gb) (1 cm spacing in .pts file format)

Sitemap_Vol_Walker_Floor_2.htm -Explore the data set in Leica TruView, which requires Leica TruView free viewer and Internet Explorer.  For instructions on using the free TruView data viewer and for a complete list of links to the TruView data related to this project, please see: Accessing Vol Walker Interior TruViews.

Please note. This data is distributed under a Creative Commons 3.0 License  (seehttp://creativecommons.org/licenses/by-nc/3.0/ for the full license). You are free to share and remix these data under the condition that you include attribution as provided here.  You may not use the data or products in a commercial purpose without additional approvals. Please attach the following credit to all data and products developed there from:

Credits:

Data was collected in collaboration with University of Arkansas Facilities Management, Operations and Maintenance and Campus Planning Divisions with outstanding assistance from Bob Harris, Construction Coordinator.

]]>
University of Arkansas – Vol Walker Building – Interior Floor 1 /region-data/region/united-states/university-of-arkansas-vol-walker-building-interior-floor-1-2/ Tue, 30 Aug 2011 00:15:53 +0000 /?p=3626 Continue reading →]]>  

Working with the University of Arkansas’ Facilities Management and Planning Departments, CAST is documenting the historical Vol Walker Building and its renovation.  Here are merged scans of the first floor of the interior, which were collected with the Z+F 5005i Scanner.  The project includes multiple floors within the building interior as well as the building exterior.  Interior scans were collected with a point spacing that ranged from less than a centimeter at the most dense (at a range of < 1 meter) to approximately 5 cm at the least dense (at a range of 25 meters).  These scans were then reduced to a more consistent point spacing of 1 cm for potential future use in historical preservation documentation.  Exterior scans were collected with a point spacing of approximately 5-10 cm.  The data sets have been separated due to file size and data density.

 

 

 

 

 

Vol_Walker_Building_Interior_Floor_1 .zip (2 gb) (1 cm spacing in .pts file format)

Sitemap_Vol_Walker_Floor_1.htm -Explore the data set in Leica TruView, which requires Leica TruView free viewer and Internet Explorer.  For instructions on using the free TruView data viewer and for a complete list of links to the TruView data related to this project, please see: Accessing Vol Walker Interior TruViews.

Please note. This data is distributed under a Creative Commons 3.0 License  (seehttp://creativecommons.org/licenses/by-nc/3.0/ for the full license). You are free to share and remix these data under the condition that you include attribution as provided here.  You may not use the data or products in a commercial purpose without additional approvals. Please attach the following credit to all data and products developed there from:

Credits:

Data was collected in collaboration with University of Arkansas Facilities Management, Operations and Maintenance and Campus Planning Divisions with outstanding assistance from Bob Harris, Construction Coordinator.

]]>
Z+F Laser Scanner Workflow: Setting up the Scanner /scanning/zf-scanning-workflow-2/ Fri, 01 Jul 2011 20:19:37 +0000 5 meters]]> /3576/zf-scanning-workflow/ Continue reading →]]> This workflow will show you how to setup the Z+F Laser Scanner prior to beginning your scan.
Hint: You can click on any image to see a larger version.

[wptabs style=”wpui-alma” mode=”vertical”]
[wptabtitle] INSTRUMENT’S COMPONENTS[/wptabtitle]

[wptabcontent]

Instrument’s Components

 

[/wptabcontent]

[wptabtitle] PRE-SCANNING CHECK[/wptabtitle] [wptabcontent]

Pre-scanning Check

1. Do not scan in rain, snow or fog

2. Protect scanner from excess moisture and rain

3. If temperatures are outside the calibrated range, an error message will display. Measuring accuracy cannot be specified if scanning proceeds

4. If the scanner is taken from a cold environment into a warm, humid one, the glass window and even the optic can fog up causing measurement error as does dust, and fingerprints

 

[/wptabcontent]

[wptabtitle] Z+F SCANNER SETUP[/wptabtitle]

[wptabcontent]

Z+F Scanner Setup

1. Set up tripod as stable and level as possible

*Never use the scanner without the tripod

2. Remove instrument from case with both hands, grasping the top with one hand on the handle and reaching under the base with the other in the space provided. Refrain from using the tribrach (base mount) to lift with as it can turn unexpectedly

3. Place instrument on tripod and secure

Always keep one hand on the handle until the scanner is firmly attached to the tripod

4. Level using the leveling screws and built-in bubble level (you will also check the level under the Tilt menu on the instrument once it is on)

5. Power Supplies: A) Li-Ion Battery Pack B) KNL-24 when working near a electric outlet

6. Check to verify that the lens is perfectly clean

 

[/wptabcontent]

[wptabtitle] M-CAM SETUP[/wptabtitle] [wptabcontent]

M-Cam Setup

1. Mount the M-Cam to the top of the scanner, upright on the same side of the scanner as the keypad and display

2. Align the two adjustment pins on the scanner with the corresponding holes in the camera mount base and fasten to the screw thread in between the pins

3. Remove the port cover that reads “Press”

4. Connect the two USB cables from the M-Cam to the USB ports. There is no particular order

5. Connect the Lemo-Plug to the right hand 7 pin connector port (it is marked with an “M”)

6. Remove the lens cover

7. Place the gray card on the magnetic on the corresponding magnetic plate on the scanner below the lens. The red dot should be nearest to the edge in the view of the camera

8. After each scan, the M-Cam will collect three sets/rotations of pictures in the vertical direction starting with the lowest rotation first.

 

[/wptabcontent]

[wptabtitle]CONTINUE TO…[/wptabtitle]
[wptabcontent] Continue to part 2 in the series, Z+F Laser Scanner: Starting Your Scan.
[/wptabcontent]