Data Viewing – Geospatial Modeling & Visualization / A Method Store for Advanced Survey and Modeling Technologies Thu, 22 Mar 2018 11:49:39 +0000 en-US hourly 1 https://wordpress.org/?v=6.9.4 Polyworks PIFEdit: Cleaning Point Cloud Data /scanning/software/polyworks/workflow-polyworks/polyworks-pifedit-cleaning-point-cloud-data/ Mon, 11 Feb 2013 23:25:30 +0000 /?p=12311 Continue reading ]]> This page will show you how to view and ‘clean’ the data in Polyworks PIFEdit.
Hint: You can click on any image to see a larger version.

[wptabs style=”wpui-alma” mode=”vertical”] [wptabtitle] POLYWORKS PIFEDIT [/wptabtitle]

[wptabcontent]

Introducing Polyworks PIFEdit:

PIFEdit is a data viewing and editing software available in the PolyWorks suite.  It is used to clean scan data of unwanted data/points before importing the data into IMAlign.

* Note:  You have to have a full license of Polyworks (w/dongle)  to be able to edit and save data out of PIFEdit (otherwise it functions only as a viewer.

Basic Navigation:

Upon opening the PIF file in PIF Edit, view the scan using the appropriate mouse buttons:

Left Button:  Rotates the scan

Middle Button: Translates the scan

Right Button: Zooms in and out on the scan

Get accustomed to the use and “feel” of these buttons because they are used in all of the PolyWorks modules.

[/wptabcontent]

[wptabtitle] VIEW DATA [/wptabtitle] [wptabcontent]

View the data from every angel to identify which data you want to keep and which data can be removed.

In this “un-cleaned” data the trees and people, in this case ROTC soldiers, are seen

In the image above, a group of ROTC soldiers were included in the scan.  Since the focus of the scan is the building, the scan data of the soldiers, the trees, and the ground in front of the building will all be removed.

Notice how the trees and the soldiers (objects in the forefront) cause shadows or holes in the scan data of the structure (object in the rear).  This can be remedied by simply acquiring another scan of the same area from another location if access and time permit another scan.

[/wptabcontent]

[wptabtitle] SELECT UNWANTED DATA [/wptabtitle] [wptabcontent]

To remove the unwanted scan data, press the space bar.  This activates the Selection dialog box.

Hold down the Shift and Ctrl keys and use the middle mouse button to make your selection.

Shift:  Enables Volumetric Selection – otherwise it is in Surface Selection mode which is only useful with polygon meshes

Ctrl:  Enables Polygonal Selection – otherwise in Freeform Selection mode

[/wptabcontent]

[wptabtitle] CONFIRM SELECTION & DELETE DATA [/wptabtitle] [wptabcontent]

Because you have to perform a volumetric selection in PIFEdit (aka it selects everything in the selection window), it is always good to double check the integrity of your selection before you delete any data.

Once you have done so you can go ahead and delete the unwanted data points from the scan.  Repeat this operation as many times as needed.

The red indicates data that has been selected. On the left we view the data from above, on the right we view the same selected data in a perspective view

 

When finished, go to File – Save As – save as name_cln.pf.

Note: Our naming convention is to tack a ‘cln’ onto the scan name or to put the cleaned data into a ‘clean’ subfolder.  As a rule of thumb – never overwrite the original data.

[/wptabcontent]

[wptabtitle] CONTINUE TO… [/wptabtitle] [wptabcontent]

For further processing in the Polyworks Suite, continue on to Importing Data into IMAlign.

[wptabcontent]
[/wptabs]

]]>
University of Arkansas – Vol Walker Building – Exterior /region-data/region/united-states/university-of-arkansas-vol-walker-building-exterior-2/ Wed, 28 Mar 2012 17:49:15 +0000 /?p=5618 Continue reading ]]> Working with the University of Arkansas’ Facilities Management and Planning Departments, CAST is documenting the historical Vol Walker Building and its renovation. Here are merged scans of the exterior of the building which were collected with the Leica C10 Scan Station scanner. The project includes multiple floors within the building interior as well as the building exterior.Exterior scans were collected with a point spacing of approximately 5-10 cm. The data sets have been separated due to file size and data density. Interior scans were collected with a point spacing that ranged from less than a centimeter at the most dense (at a range of < 1 meter) to approximately 5 cm at the least dense (at a range of 25 meters). These scans were then reduced to a more consistent point spacing of 1 cm for potential future use in historical preservation documentation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vol_Walker_Building_Exterior .zip (41.9 mb) (7.5 cm spacing in .pts file format)

Sitemap_Vol_Walker_Exterior.htm -Explore the data set in Leica TruView, which requires Leica TruView free viewer and Internet Explorer.  For instructions on using the free TruView data viewer and for a complete list of links to the TruView data related to this project, please see: Accessing Vol Walker Interior TruViews.

Please note. This data is distributed under a Creative Commons 3.0 License  (seehttp://creativecommons.org/licenses/by-nc/3.0/ for the full license). You are free to share and remix these data under the condition that you include attribution as provided here.  You may not use the data or products in a commercial purpose without additional approvals. Please attach the following credit to all data and products developed there from:

Credits:

Data was collected in collaboration with University of Arkansas Facilities Management, Operations and Maintenance and Campus Planning Divisions with outstanding assistance from Bob Harris, Construction Coordinator.

]]>
University of Arkansas – Vol Walker Building – Interior Basement Level /region-data/region/united-states/university-of-arkansas-vol-walker-building-interior-basement-level-2/ Wed, 28 Mar 2012 17:32:28 +0000 /?p=5603 Continue reading ]]> Working with the University of Arkansas’ Facilities Management and Planning Departments, CAST is documenting the historical Vol Walker Building and its renovation. Here are merged scans of the basement or ground floor of the interior, which were collected with the Z+F 5005i Scanner. The project includes multiple floors within the building interior as well as the building exterior. Interior scans were collected with a point spacing that ranged from less than a centimeter at the most dense (at a range of < 1 meter) to approximately 5 cm at the least dense (at a range of 25 meters). These scans were then reduced to a more consistent point spacing of 1 cm for potential future use in historical preservation documentation. Exterior scans were collected with a point spacing of approximately 5-10 cm. The data sets have been separated due to file size and data density.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vol_Walker_Building_Interior_Basement .zip (4.4 mb) (1 cm spacing in .pts file format)

Sitemap_Vol_Walker_Basement.htm -Explore the data set in Leica TruView, which requires Leica TruView free viewer and Internet Explorer.  For instructions on using the free TruView data viewer and for a complete list of links to the TruView data related to this project, please see: Accessing Vol Walker Interior TruViews.

Please note. This data is distributed under a Creative Commons 3.0 License  (seehttp://creativecommons.org/licenses/by-nc/3.0/ for the full license). You are free to share and remix these data under the condition that you include attribution as provided here.  You may not use the data or products in a commercial purpose without additional approvals. Please attach the following credit to all data and products developed there from:

Credits:

Data was collected in collaboration with University of Arkansas Facilities Management, Operations and Maintenance and Campus Planning Divisions with outstanding assistance from Bob Harris, Construction Coordinator.

 

 

]]>
University of Arkansas – Vol Walker Building – Interior Basement Level /scanning/university-of-arkansas-vol-walker-building-interior-basement-level-3/ Wed, 28 Mar 2012 17:32:28 +0000 5 meters]]> /?p=5603 Continue reading ]]> Working with the University of Arkansas’ Facilities Management and Planning Departments, CAST is documenting the historical Vol Walker Building and its renovation. Here are merged scans of the basement or ground floor of the interior, which were collected with the Z+F 5005i Scanner. The project includes multiple floors within the building interior as well as the building exterior. Interior scans were collected with a point spacing that ranged from less than a centimeter at the most dense (at a range of < 1 meter) to approximately 5 cm at the least dense (at a range of 25 meters). These scans were then reduced to a more consistent point spacing of 1 cm for potential future use in historical preservation documentation. Exterior scans were collected with a point spacing of approximately 5-10 cm. The data sets have been separated due to file size and data density.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vol_Walker_Building_Interior_Basement .zip (4.4 mb) (1 cm spacing in .pts file format)

Sitemap_Vol_Walker_Basement.htm -Explore the data set in Leica TruView, which requires Leica TruView free viewer and Internet Explorer.  For instructions on using the free TruView data viewer and for a complete list of links to the TruView data related to this project, please see: Accessing Vol Walker Interior TruViews.

Please note. This data is distributed under a Creative Commons 3.0 License  (seehttp://creativecommons.org/licenses/by-nc/3.0/ for the full license). You are free to share and remix these data under the condition that you include attribution as provided here.  You may not use the data or products in a commercial purpose without additional approvals. Please attach the following credit to all data and products developed there from:

Credits:

Data was collected in collaboration with University of Arkansas Facilities Management, Operations and Maintenance and Campus Planning Divisions with outstanding assistance from Bob Harris, Construction Coordinator.

 

 

]]>
University of Arkansas – Vol Walker Building – Interior Floor 3 /region-data/region/united-states/university-of-arkansas-vol-walker-building-interior-floor-3-2/ Wed, 28 Mar 2012 17:25:57 +0000 /?p=5600 Continue reading ]]> Working with the University of Arkansas’ Facilities Management and Planning Departments, CAST is documenting the historical Vol Walker Building and its renovation. Here are merged scans of the third floor of the interior, which were collected with the Z+F 5005i Scanner. The project includes multiple floors within the building interior as well as the building exterior. Interior scans were collected with a point spacing that ranged from less than a centimeter at the most dense (at a range of < 1 meter) to approximately 5 cm at the least dense (at a range of 25 meters). These scans were then reduced to a more consistent point spacing of 1 cm for potential future use in historical preservation documentation. Exterior scans were collected with a point spacing of approximately 5-10 cm. The data sets have been separated due to file size and data density.

 

 

 

 

 

 

 

 

 

 

 

 

 

Vol_Walker_Building_Interior_Floor_3 .zip (4.4 mb) (1 cm spacing in .pts file format)

Sitemap_Vol_Walker_Floor_3.htm -Explore the data set in Leica TruView, which requires Leica TruView free viewer and Internet Explorer.  For instructions on using the free TruView data viewer and for a complete list of links to the TruView data related to this project, please see: Accessing Vol Walker Interior TruViews.

Please note. This data is distributed under a Creative Commons 3.0 License  (seehttp://creativecommons.org/licenses/by-nc/3.0/ for the full license). You are free to share and remix these data under the condition that you include attribution as provided here.  You may not use the data or products in a commercial purpose without additional approvals. Please attach the following credit to all data and products developed there from:

Credits:

Data was collected in collaboration with University of Arkansas Facilities Management, Operations and Maintenance and Campus Planning Divisions with outstanding assistance from Bob Harris, Construction Coordinator.

]]>
Working with terrestrial scan or photogrammetrically derived meshes in ArcGIS. /modeling/software-visualization/rapidform-xor/workflow-rapidform-xor/working-with-terrestrial-scan-or-photogrammetrically-derived-meshes-in-arcgis/ Mon, 12 Dec 2011 16:59:53 +0000 /4039/working-with-terrestrial-scan-or-photogrammetrically-derived-meshes-in-arcgis/ Continue reading ]]> [wptabs mode=”vertical”] [wptabtitle] Introduction[/wptabtitle] [wptabcontent]

Many archaeological projects use a GIS to manage their data. After terrestrial scan or photogrammetric modeling data has been collected and cleaned, it may be convenient to integrate it into a project’s GIS setup. As ArcGIS is widely available and in use both in University research departments and government offices, we’re using it for the example here, but something like this should work for other GIS packages.

The first part of the workflow addresses working with meshes created from terrestrial scan data, and assumes you have existing meshes in Rapidform.

[/wptabcontent]

[wptabtitle] Decimation[/wptabtitle] [wptabcontent]

Before exporting a dataset for use in a GIS you may want to decimate the dataset to produce a lower resolution model for visualization. High resolution models can slow rendering down and make manipulation of the model difficult.

a. Select the model you will be exporting either graphically or through the menu tree on the left hand side of the screen.

b. In the main menu select Tools and then Scan Tools and Decimate Meshes

clip_image002

Fig. 1: Select the Decimate Meshes tool

c. In the Decimate Meshes menu confirm the selection of the Target Mesh.

d. Under Method choose Poly-Face Count for best control over the size of the resultant model.

e. Under Options set the Target Poly-Face Count. Numbers under 100,000 will render relatively quickly in ArcGIS. Inclusion of more than 500,000 polyfaces is not recommended.

f. Under More Options select Preserve Color.

g. Click “OK” to confirm and decimate the mesh.

clip_image004

Fig. 2: Select options for decimating the mesh.

[/wptabcontent]

[wptabtitle] Subsetting and Splitting Meshes[/wptabtitle] [wptabcontent]

(Skipping ahead a bit conceptually…) When you import your mesh data into ArcGIS each mesh is stored as a single multipatch. You don’t want to edit the shape of the multipatch in ArcGIS, only the placement (trust us on this). So any subsetting of the mesh needs to be performed before exporting from Rapidform (or other modeling software of your choice). Why subset or split a mesh?

a. Navigating in tight, enclosed spaces. You might want to be able to turn off the visibility of the back wall of a room or one half of a cistern to better visualize its interior.

b. Major sections of a mesh. If you have a scan of a building including several rooms or structures and you want to be able to visualize them individually, then they need to be made into discrete meshes.

[/wptabcontent]

[wptabtitle] Exporting[/wptabtitle] [wptabcontent]

a. Select the model you want to export from the menu tree on the left hand side of the screen.

b. Right-click and select “Export”. Select an appropriate file format (see step 2, below, for choices).

clip_image006

Fig. 3: Export via the menu tree.

4. Export Formats

a. Get a list of valid export formats by looking in the dropdown menu of the export dialog box.

clip_image008

Fig. 4: Valid export file formats.

b. Suggested formats for export are VRML (file extension .wrl), collada (.dae) and AutoDesk 3d Max (.3ds).

[/wptabcontent][wptabtitle] Advice on Textures and Color Data[/wptabtitle] [wptabcontent]

Modeling software manages color data in several ways. Color data might be recorded as UV coordinates referencing a separate texture file, as per vertex, per face or per wedge color information. Color data imported with scan data will typically default to storage as per vertex color. ArcGIS only recognizes color data stored explicitly in texture files, so if your color data is currently stored in another form you need to convert it.

[/wptabcontent]

[wptabtitle] Textures direct from Rapidform[/wptabtitle] [wptabcontent]

i. Select the Mesh mode from the main toolbar.

clip_image010

ii. Select Tools and Texture Tools and Convert Color to Texture. clip_image012

Fig. 5: Conver Color to Texture

 

iii. After creating the texture, export the model as usual.

iv. Export the texture by going in the Main Menu to Texture Tools, then Export Texture to save the texture file. Store it in the same folder as the model.[/wptabcontent]

[wptabtitle] Color and Texture in Meshlab[/wptabtitle] [wptabcontent]Sometimes you want more tools for color editing. Sometimes ArcGIS doesn’t like the textures produced by Rapidform. For this reason, we suggest an alternative method for setting the texture data using Meshlab. Meshlab is open source, and can be found at meshlab.sourceforge.net.

i. From Rapidform export a .VRML file by right-clicking (in the model tree menu on the left land side of the screen) on the mesh you wish to export and selecting Export.

ii. In Meshlab, open a new empty project. Go to File and Import Mesh.

clip_image014

Fig. 6: Import the Mesh to Meshlab

iii. Select the VRML file you just created and hit Open.

iv. Transfer the color information from per vertex to per face. In the main menu go to Filters, then to Color Creation and Processing, then to Transfer Color: Vertex to Face. Hit Apply in the resulting pop-up menu.

clip_image016

Fig. 7: Transfer color data from the vertices to the faces of the mesh.

v. From the Main Menu go to Filters, then to Texture, then to Trivial Per-Triangle Parametrization.

clip_image018

Fig. 8: Create texture data.

In the pop-up menu, select 0 Quads per line, 1024 for the Texture Dimension, and 0 for Inter-Triangle border. Choose the Space Optimizing method. Click Apply.

n.b. If you get an error along the lines of “Inter-Triangle area is too much” your Texture Dimension is too small for the dataset. Increase the texture dimension to resolve the error.

clip_image020

Fig. 9: Set the texture data parameters.

vi. In the Main Menu go to Filters and Texture and Vertex Color to Texture. Accept the defaults for the name and size. Tick the boxes next to Assign texture and Fill Texture.

clip_image022

Fig. 10: Transfer color data to the texture dataset.

 

vii. In the Main Menu go to File and Export Mesh. Make sure to UNTICK the box next to Vertex Color. Otherwise ArcGIS gets confused! Make sure the texture file is present. Click OK to save.

clip_image024

Fig. 11: Export the mesh as collada (dae).[/wptabcontent]

[wptabtitle] Preparing a GIS to receive Mesh data[/wptabtitle] [wptabcontent]

Once you have created your mesh files and exported them to collada or something similar and explicitly assigned texture data (not to be confused with vertex color, face color or wedge color data), you are ready to import the data into ArcGIS. Assuming your data is not georeferenced, follow the method below. If your data is georeferenced, head over to our Photoscan to ArcGIS post, and follow the import method described there.

1. Preparing the geodatabase

a. Open ArcCatalog any way you choose. Create a new geodatabase by right clicking on the folder where you wish to create the geodatabase and selecting New and File Geodatabase. Only Geodatabases support the import of texture data, so don’t try and use a shapefile.

clip_image027

Fig. 14: Create a geodatabase in ArcGIS.

b. Create a multipatch feature class in the geodatabase.

c. Ensure that the X/Y domain covers the coordinates of any meshes you will be importing. View the Spatial Domain by right-clicking on the feature class and going to Properties and then to the Domain tab.

clip_image029

Fig. 15: Check the spatial domain of the new feature class.

d.If the spatial domain is not suitable, adjust the Environment settings by going to the Geoprocessing toolbar in the Main Menu. Scroll down to Geodatabase Advanced and adjust the Output XY Domain as needed. You can also adjust the Z Domain in this dialog box.

clip_image031

Fig. 16: Adjust the spatial domain in the environment settings.

[/wptabcontent]

[wptabtitle] Preparing the scene file. [/wptabtitle] [wptabcontent]

a. Open ArcScene and add base data such as a plan of the site, an air photo of the location, etc. The base data will allow you to control the location to which the model is imported. Add the empty multipatch feature class you just created.

clip_image033

Fig. 17: Add base data to a Scene.

b. Start editing either from the 3D editor toolbar or by right-clicking on the multipatch feature class in the Table of Contents and choosing Edit Features and Start Editing.

clip_image035

Fig. 18: Start editing in ArcScene. [/wptabcontent][wptabtitle] Importing the Scan data[/wptabtitle] [wptabcontent]

1. Import the vrml or collada file by selecting the Create Features Template for the multipatch and clicking on the base plan roughly in the location where you would like the mesh data to appear. Select the vrml or collada file from the Open File dialog box that appears. Wait while the file is converted.

clip_image037

Fig. 19: The vrml data is converted to multipatch on import.

2. You can now Move, Rotate, Scale the imported multipatch in ArcScene by selecting the feature using the Edit Placement tool and inputting values in the 3D Editing toolbar or by interactively dragging the multipatch feature.

clip_image039

Fig. 20: Select the multipatch feature to adjust its position and scale.

3. Once you are satisfied with the placement of the multipatch, you can add attribute data.

[/wptabcontent]

[wptabtitle] A note on rotation in Arcscene[/wptabtitle] [wptabcontent]

You can only rotate in the x-y plane (that is, around z-axis) in ArcScene. If you need to rotate your data around the x or y axis you need to do this in your modeling software before import. Bringing a .dxf of the polygon or point data you are trying to align the mesh with into your modeling software is probably the simplest way to get the alignment right. You may have to translate your .dxf to a local grid because most modeling software doesn’t like real world coordinates. Losing the real coordinates during this step doesn’t matter because you’re just using the polygon data to set orientation around the x and y axes. You’ll get the model in the correct real-world place when you import into ArcScene.

clip_image041

[/wptabcontent]

[wptabtitle] Re-exporting[/wptabtitle] [wptabcontent]

Fig. 21: The textured mesh data appears over the correct location on the base plan.

4. At this point it’s probably a good idea to re-export a collada model of your newly scaled and located mesh data. If not, every time you update the model you will have to go through the scaling and locating process again.

a. In ArcToolbox go to Conversion Tools> To Collada> Multipatch To Collada. clip_image043

Fig. 22: Export Multipatch to Collada

b. Select the multipatch for export and the folder where you want the re-exported model to appear.

clip_image045

Fig. 23: Set parameters for export.

c. Check that the model has exported correctly by opening it in your modeling software.

n.b. You may have to reapply the textures at this point.

[/wptabcontent]

[wptabtitle] A note on features for attribute management [/wptabtitle] [wptabcontent]

It may be convenient to store attribute information in other related feature classes so that a single meshed model can have multiple, spatially discrete attributes. How you design your geodatabase will vary greatly dependent on project requirements.

clip_image047

Fig. 19: Additional related feature classes can be used to manage attribute data.

[/wptabcontent]

[wptabtitle] A note on just how much mesh data you can get into ArcScene.[/wptabtitle] [wptabcontent]

1. If you are using a file geodatabase, in theory the size of the geodatabase is unlimited and you can include all the mesh data you want.

2. In practice, individual meshes with more than 200,000 polygons have problems importing on an average ™ desktop computer.

3. In practice, rendering becomes slow and jumpy with more than 200 MB of mesh data loaded into a single scene on an average ™ desktop computer. The size and quality of your textures will also have an impact here. Compressed textures are probably a good plan.

4. In short, the limitation is on rendering and on what can be cached in an individual scene, rather than on storage in the geodatabase. Consider strategies including having low polygon count meshes for display in a general scene, with links to high polygon count meshes, which can be stored in the geodatabase but not normally rendered in the scene, which can be called up via links in html popup, the attribute table, or via another script.

[/wptabcontent]

[/wptabs]

]]>
University of Arkansas – Vol Walker Building – Interior Floor 2 /region-data/region/united-states/university-of-arkansas-vol-walker-building-interior-floor-2-2/ Tue, 30 Aug 2011 00:50:10 +0000 /?p=3634 Continue reading ]]>  

Working with the University of Arkansas’ Facilities Management and Planning Departments, CAST is documenting the historical Vol Walker Building and its renovation.  Here are merged scans of the second floor of the interior, which were collected with the Z+F 5005i Scanner.  The project includes multiple floors within the building interior as well as the building exterior.  Interior scans were collected with a point spacing that ranged from less than a centimeter at the most dense (at a range of < 1 meter) to approximately 5 cm at the least dense (at a range of 25 meters).  These scans were then reduced to a more consistent point spacing of 1 cm for potential future use in historical preservation documentation.  Exterior scans were collected with a point spacing of approximately 5-10 cm.  The data sets have been separated due to file size and data density.

Vol_Walker_Building_Interior_Floor_2 .zip (2.81 gb) (1 cm spacing in .pts file format)

Sitemap_Vol_Walker_Floor_2.htm -Explore the data set in Leica TruView, which requires Leica TruView free viewer and Internet Explorer.  For instructions on using the free TruView data viewer and for a complete list of links to the TruView data related to this project, please see: Accessing Vol Walker Interior TruViews.

Please note. This data is distributed under a Creative Commons 3.0 License  (seehttp://creativecommons.org/licenses/by-nc/3.0/ for the full license). You are free to share and remix these data under the condition that you include attribution as provided here.  You may not use the data or products in a commercial purpose without additional approvals. Please attach the following credit to all data and products developed there from:

Credits:

Data was collected in collaboration with University of Arkansas Facilities Management, Operations and Maintenance and Campus Planning Divisions with outstanding assistance from Bob Harris, Construction Coordinator.

]]>
University of Arkansas – Vol Walker Building – Interior Floor 1 /region-data/region/united-states/university-of-arkansas-vol-walker-building-interior-floor-1-2/ Tue, 30 Aug 2011 00:15:53 +0000 /?p=3626 Continue reading ]]>  

Working with the University of Arkansas’ Facilities Management and Planning Departments, CAST is documenting the historical Vol Walker Building and its renovation.  Here are merged scans of the first floor of the interior, which were collected with the Z+F 5005i Scanner.  The project includes multiple floors within the building interior as well as the building exterior.  Interior scans were collected with a point spacing that ranged from less than a centimeter at the most dense (at a range of < 1 meter) to approximately 5 cm at the least dense (at a range of 25 meters).  These scans were then reduced to a more consistent point spacing of 1 cm for potential future use in historical preservation documentation.  Exterior scans were collected with a point spacing of approximately 5-10 cm.  The data sets have been separated due to file size and data density.

 

 

 

 

 

Vol_Walker_Building_Interior_Floor_1 .zip (2 gb) (1 cm spacing in .pts file format)

Sitemap_Vol_Walker_Floor_1.htm -Explore the data set in Leica TruView, which requires Leica TruView free viewer and Internet Explorer.  For instructions on using the free TruView data viewer and for a complete list of links to the TruView data related to this project, please see: Accessing Vol Walker Interior TruViews.

Please note. This data is distributed under a Creative Commons 3.0 License  (seehttp://creativecommons.org/licenses/by-nc/3.0/ for the full license). You are free to share and remix these data under the condition that you include attribution as provided here.  You may not use the data or products in a commercial purpose without additional approvals. Please attach the following credit to all data and products developed there from:

Credits:

Data was collected in collaboration with University of Arkansas Facilities Management, Operations and Maintenance and Campus Planning Divisions with outstanding assistance from Bob Harris, Construction Coordinator.

]]>
Tiwanaku, Bolivia – Digital Elevation Model (1972) /scanning/tiwanaku-boliviadem-2/ Fri, 17 Jun 2011 21:49:48 +0000 /?p=3494 Continue reading ]]> The Center has been involved in a multi-year project in collaboration with Dr. Alexei Vranich at the University of Pennsylvania to scan and document the Pre-Incan site of Tiwanaku, Bolivia.  Read a short synopsis of the project at Tiwanaku Project Details and for full details on the entire survey, refer to Geophysics and Geomatics at Tiwanaku.

For the .jpg, .tif, or .img photogrammetry formats, we recommend the free viewer ArcGIS Explorer Desktop. This free GIS application provides ways to explore and share GIS data.

digital elevation model DEM made using photogrammetric techniques on 10 vertical aerial photographs of Tiwankau, Bolivia center for advanced spatial technologies CAST, University of Arkansas Adam Barnes

dem_1972_1m.tif (File size – 71 mb)

Photogrammetric processing was performed on 10 historic vertical aerial photographs from 1972 to produce this digital elevation model (DEM) covering the monumental core and surrounding areas of Tiwanaku.
Ground sample distance – 0.5-m
Coverage – 330-ha
Coordinate system – Arbitrary, based on local coordinate system used by archaeologists.

Please note. This data is distributed under a Creative Commons 3.0 License (see http://creativecommons.org/licenses/by-nc/3.0/ for the full license). You are free to share and remix these data under the condition that you include attribution as provided here. You may not use the data or products in a commercial purpose without additional approvals. Please attach the following credit to all data and products developed there from:
Credit: Museum of Archeology and Anthropology, General Robotics, Automation, Sensing and Perception (GRASP) Lab (University of Pennsylvania) and Center for Advanced Spatial Technologies, (University of Arkansas)
Longer version: Data acquired, processed and distributed by the Center for Advanced Spatial Technologies staff and University of Pennsylvania.

 

]]>
Tiwanaku, Bolivia – Digital Elevation Model (1992) /scanning/tiwanaku-bolivia-digital-elevation-model-1992-2/ Fri, 17 Jun 2011 18:31:42 +0000 /?p=3469 Continue reading ]]>  

The Center has been involved in a multi-year project in collaboration with Dr. Alexei Vranich at the University of Pennsylvania to scan and document the Pre-Incan site of Tiwanaku, Bolivia.  Read a short synopsis of the project at Tiwanaku Project Details and for full details on the entire survey, refer to Geophysics and Geomatics at Tiwanaku.

For the .jpg, .tif, or .img photogrammetry formats, we recommend the free viewer ArcGIS Explorer Desktop. This free GIS application provides ways to explore and share GIS data.

digital elevation model DEM made using photogrammetric techniques on 2 vertical aerial photographs of Tiwankau, Bolivia center for advanced spatial technologies CAST, University of Arkansas Adam Barnes

dem_1992_1m.tif (File size – 26 mb)

Photogrammetric processing was performed on two historic vertical aerial photographs from 1992 to produce this digital elevation model (DEM) covering the monumental core and surrounding areas of Tiwanaku.
Ground sample distance – 1-m
Coverage – 550-ha
Coordinate system – Arbitrary, based on local coordinate system used by archaeologists.

Please note. This data is distributed under a Creative Commons 3.0 License (see http://creativecommons.org/licenses/by-nc/3.0/ for the full license). You are free to share and remix these data under the condition that you include attribution as provided here. You may not use the data or products in a commercial purpose without additional approvals. Please attach the following credit to all data and products developed there from:
Credit: Museum of Archeology and Anthropology, General Robotics, Automation, Sensing and Perception (GRASP) Lab (University of Pennsylvania) and Center for Advanced Spatial Technologies, (University of Arkansas)
Longer version: Data acquired, processed and distributed by the Center for Advanced Spatial Technologies staff and University of Pennsylvania.

 

]]>