Z+F Laser Scanner: Starting your Scan

This workflow will show you how to start a scan using the Z+F Laser Scanner.
Hint: You can click on any image to see a larger version.

[wptabs style=”wpui-alma” mode=”vertical”] [wptabtitle] POSITIONING AND POWERING UP THE SCANNER[/wptabtitle] [wptabcontent]

1. Position the scanner in the center of the target field

Ensure that the angle of incidence of the laser on the target is larger than 45 degrees

 

Recommended distance between the Z+F scanner and targets

RESOLUTION RECOMMENDED DISTANCE WITH AN ANGLE OF 90 deg.
Middle 1 m to 15 m
High 1 m to 20 m
Super High 1 m to 25 m
Ultra High 1 m to 30 m

With smaller a smaller angle of incidence the target distance is reduced

Power the scanner on by pressing the power button for 0.3 seconds

The power-up process takes approx. 20 seconds in which time it will rotate while the mirror spins

[/wptabcontent]

[wptabtitle] MENUS AND CONTROLS[/wptabtitle] [wptabcontent]

Menus and Controls

System Menu shown in the display. Main menu order:

· Info

· Status

· Tilt Sensor

· Scanning

· Data Management

Control buttons:

clip_image004[/wptabcontent]

[wptabtitle]SCAN MENU SYMBOLS[/wptabtitle]

[wptabcontent]Scan Menu Symbols

The top line indicates the menu currently in use

clip_image006

See User Manual for full descriptions of all menus

Check the Tilt Sensor Menu

If the inclination in f the Y-direction is greater than or less than 2 degrees, an arrow will appear and the inclination should be corrected[/wptabcontent]

[wptabtitle] THE SCANNING MENU[/wptabtitle] [wptabcontent]In the Scanning Menu

RESOLUTION:

Select the preferred resolution level (Middle or High is usually preferred)

Super High, High and Middle resolutions have a low noise option that reduces noise by the factor of 1.4, but scanning time is doubled

VERTICAL SCAN RANGE:

You can select predefined vertical scan ranges using the + / – buttons or further refine each predefined range by pressing the clip_image007 button and increasing or decreasing the values by 5 deg. with the + / – buttons. Predefined ranges include:

· V 0-360

· V 25-160 and 200-335

· V25-180

· V 180-260

· V 45-135

HORIZONTAL SCAN RANGE:

The horizontal scan range can be set in increments of 5 deg. for both the start and end position using the + / – buttons and pressing the clip_image008 button to confirm the position

Alternatively the scanner start position can be manually set by rotating the scanner to any position greater than 0.0. Press the clip_image009 button to confirm the position. Set the horizontal range end position next in the same manner[/wptabcontent]

[wptabtitle] START THE SCAN[/wptabtitle]

[wptabcontent]Start the Scan

Press the clip_image010 button to start the scanning process. The process can also be stopped using this button and all data collected prior to interruption will be stored.
[/wptabcontent]

[/wptabs]

Comments are closed.